Email: info@mineddy.com        Tel: +86 25 58889257

PRODUCTS
All categories

Nanjing Mineddy Medical Equipment Co., Ltd.

+86 18551821908 (whatsapp)

MDOT-003 Electric operating table

零售价
0.0
Yuan
市场价
0.0
Yuan
浏览量:
1000
产品编号
所属分类
无分类内容
数量
-
+
库存:
0
1
Product description
[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[产品参数, 参数]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]

1、Description

1.1 Use and brief introduction

The product belongs to class I, type B. Non AP or APG device , continuous device. And possesses application part.

PLEOT-003 is designed specially to meet the different demands of the market and according to the common advice of users.

Operating table is used for general Ophthalmologic operations, it uses electric pressure, with a switch to control its elevation (up/down),easy to operating and it is reliable. The operating table is widely used, easy to operate and adjust with reliable performance, which is a ideal table for different hospital.

High degree of automation and low noise, reliable, key parts are imported.

Be sure to read the instruction carefully before using, and keep it.

1.2 Product formation and feature

1.2.1 Product formation

The operating is formed by head plate and back plate, waist plate, buttocks plate and leg. Diagram of structure Electric operating table Please look at the Picture 1

 

diagram

 

Picture 1 Diagram of structure PLEOT-003 Electric operating table

1.2.2 Feature

a) You can adjust the height of the table as you wish(look at picture 1),convenient for doctors.

b) The tabletop and base adopt frame construction,the cushion won’t move when the table works,and then you can take the cushion apart from the table for cleanup.

diagram

2 Instruction

2.1 General content

2.1.1basic data

The technical data should look at picture 1

Picture 1 basic data         unit:mm

Basic
data
Model

length

Width

Highest and lowest height of tabletop

Distance of elevation

L

B

h min

s

PLEOT-003

≥1960

550±20

680±50

≥300

2.1.2 Gross weight、net weight、volume

Gross weight:290㎏,net weight:247㎏,Volume(long×width×height)1400㎜×750㎜×960㎜。

2.1.3 Safe working load

the safe working load of the table is 173kg(Look at picture 2),back plate is 50kg,buttocks plate 98kg,leg plate is 25kg,

to ensure safe operations.

2.2 using attentions:

2.2.1 attention

a)The table should be kept in a clean place, never put it in the places where influenced

by atmospheric pressure, temperature, humidity, aeration, sunshine ,or dust and sulfur.

b)Be careful when you transport the table

c)The table should be kept separately from chemicals.

d) Please pay attention to the supply frequency、electric tension and nominal impedance;

e)Should choose anti-static cushion.

2.2.2 Attentions:

a) Please read the instruction before using. People who doesn’t know the operating method is forbidden to use.

b) Check the switch , and be sure they can work.

c) Please confirm all the power line are connected aright, safely;

d) When it work with high frequency surgical equipment,the equipment should comply with GB9706.1.

2.2.3 Using attention:

a) Please check the operating table from time to time;

b) Once found it is out of work, please stop using.

c) Make sure that the patient won’t touch the table.

d) Please don’t take them down when they are out of work,and contact the serviceman in time ;

e) When change the fuse, you should turn off the power;

f) It should be separated from the magnetic field when using.

g) Only When tabletop slides backward in place, can back plate go down.

When back plate goes down, tabletop can never slide forward.

h) When tabletop slides forward, back plate should firstly go up to 5°.

i) When tabletop lateral tilt to 7°,tabletop won’t function the trendelenburg.

j) When tabletop’s trendelenburg at 7°,tabletop cannot function the lateral tilt.

k) when the battery without power, please plug the power cord into a outlet and then activate the battery charge board by pressing any button on the hand remote to get fully charged.

2.2.4 attention after using

a) To return to the former condition,and turn it off,cut off the electricity supply;

b) Put the telecontroller in the right place;

c) Clean the table after operations.

2.3 Cleanout, disinfection and sterilization

Turn off the power after operations, the cushion should be cleaned twice by 75% alcohol and then use disinfector and ultraviolet radiation for sterilization.

2.4 Method of operation

2.4.1 Preparations before using

a) electric tension:220V、frequency :50Hz;

b) No objects exist that affect the operations;

c) Confirm if all the power lines are connected well,the switch is in” 0” condition;

d) Move the table to the right place you need;

e) Connect the controller with the table;

f) Please check the power supply before turning it on;

g) Lock the base of the table;

h) The table adopts short-time work,attention:never press one button over 2min.

2.4.2 operating method

a) Adjustment of leg plate

Slacken the handle between leg plate and buttocks plate,put it to a proper place and screw up the handle

b) Fixing of accessories

There is rail on the both side of the table,you can use the fixing clamp the set up all the accessories.

2.4.3 Functions of telecontroller

diagram

2.4.4 Picture of control panel

a) power supply jack:220V

IN AC socket;

b) Switch” |”means” ON”

“O”means “OFF”

fuse:F2A 2 piece、F10A 1 piece;

diagram

3 、maintenance

3.1 Users should check the table and maintain it from time to time.

3.2When the table hasn’t been used for long time, you need to check it before using.

3.3There is enough oil in the oil pump when leave the factory. If you find the oil is not enough, you can add N46 oil.

3.4 In order to prolong its using life and keep it in a good condition, you need to pay attention to the daily maintenance and add lubricant oil.

3.5You cannot use caustic cleaner to clean the cushion after operations.

3.6Please lower the lowest position after using.

3.7When it cannot work any more,the scrap of the equipment should comply with legal regulations.

4 Main technical data and working environment required

4.1 Main technical data

4.1.1 please check picture 2.

Picture 2 Main technical data

NO.

item

Basic data

NO.

item

Basic data

1

Trendelenburg

Forward

≥25°

4

Back plate

Up

≥75°

Backward

≥25°

Down

≥10°

2

Lateral tilt

Left

≥20°

5

Leg plate

Down

≥90°

Right

≥20°

out

≥90°

3

Head plate

Up

≥45°

6

Elevation of kidney bridge

≥80mm

Down

≥90°

7

sliding

≥340mm

4.1.2 Input power:650VA。

4.2 working environment required

a)temperature:10℃~40℃

b) relative humidity:≤80%

c) atmospheric pressure:760hPa~1060hPa

4.3 power requirements

a) supply voltage :~220V±10%;

b) supply frequency:50Hz±2%;

c) Power capacity:≥1kw;

4.4 Transportation and storage requirement

It could be stocked more than 15 weeks as follow conditions:

a)temperature:-30~55℃

b) relative humidity:≤95%

c) atmospheric pressure:500~1060hPa

d) stock in a ventilated place

5、 Common problems and solutions

5.1 attention

a) All the electric elements , hydraulic elements and oil pump are in the base of the table. When you repair them, you should open the cover of the base firstly,make sure you have cut off the electricity and power before doing this;

b) Method of open the base:adjust the tabletop to the highest position,screw off the screw,and then take it apart from the table;

c) When you open the cover,Please remove the collet of line pipe firstly;

d) Screw off the 4 screws,take t,adjust the tabletop to a little higher,and lock the base,then you can start repairing.

5.2 Common problems and solutions

a) Wrong operations

problem:when you press only one button, but over one action worked

cause:the elements of the base become damp.

Solution:use gauze to dry it,and adopt 300V blow drier .

The table cannot work:

cause1:disabled fuse 。

cause2:the jack of controller has loosen.

solution1:replace fuse

solution 2 connect the power of controller with the table again

b) Some buttons cannot work:

Cause 1:the button are out of work.

Cause 2:the jack didn’t connect well.

Solution:you can replace the buttons or jack

c) Oil is not enough

Problem:the tabletop cannot rise to highest position.

solution:open the oilcan,add the oil to the 3/5 of the total volume.

6、 Packing list

Picture 3 Packing list

NO.

Item

quantity

NO.

Item

Quantity

1

Anaesthesia screen

1 piece

10

Fixing clamp

2 piece

2

Shoulder support(cushion)

2 piece

11

Telecontroller

1 piece

3

Body support(cushion)

2 piece

12

Power line

1 piece

4

Arm support(cushion)

2 piece

13

T2A fuse

2 piece

5

Leg support(wrapper)

2 piece

F10A fuse

1 piece

6

Head plate(cushion)

1 piece

14

oilcan(with oil)

1 piece

7

leg plate(cushion)

2 piece

15

Quality certificate

1 piece

8

cushion

1 piece

16

Instruction

1 piece

9

Foot plate(cushion0)

2 piece

17

guarantees of repair

1 piece

7、 Circuit diagram

diagram

扫二维码用手机看
未找到相应参数组,请于后台属性模板中添加
上一个
下一个

Contact Us

Start a conversation

Username used for comment:
Customer message
Description:
验证码

Copyright © 2020 Nanjing Mineddy Medical Equipment Co., Ltd   苏ICP备17075856号-1   power by www.300.cn